Splanchnic and systemic hemodynamics in mice using a radioactive microsphere technique
Journal Article
·
· American Journal of Physiology; (USA)
OSTI ID:6920170
- Veterans Administration Medical Center, West Haven, CT (USA)
Mice are commonly used for the study of human disease processes. However, techniques for measuring systemic and hepatic blood flow in mice have not been developed. We attempted the conventional technique of radiolabeled microsphere injection into the left ventricle, but difficulties were encountered, including unsuspected ventricular perforation and outflow obstruction in 68% of the animals. We therefore evaluated whether an injection into the carotid artery close to the aortic arch can fulfill the criteria (approximately or greater than 300 microspheres in femoral blood or tissues, adequate mixing of microspheres with blood, and no significant alteration of blood pressure during microsphere injection) required for accurate measurement of systemic and regional hemodynamics. Carotid artery injection resulted in adequate mixing and number of microspheres in tissues in 78 and 91% of the animals, respectively. Portal venous inflow was 1.8 +/- 0.3 ml.min-1.g liver tissue-1 and renal blood flow was 5.1 +/- 0.75 ml.min-1.g tissue-1. Compared per unit weight, these values are quite similar to those reported in rats. Cardiac output was 12.1 +/- 1.2 ml/min and cardiac index was 462 +/- 47 ml.min-1.kg body wt-1. The reliability of cardiac output determination is improved if whole body radioactivity is taken into account. Five of 22 animals had to be excluded because of either a low number of microspheres in tissues or inadequate mixing of microspheres with blood (shown by asymmetrical distribution of microspheres between left and right kidney). With modifications, the radioactive microsphere technique can be adapted to the hemodynamic study of mice.
- OSTI ID:
- 6920170
- Journal Information:
- American Journal of Physiology; (USA), Journal Name: American Journal of Physiology; (USA) Vol. 258; ISSN 0002-9513; ISSN AJPHA
- Country of Publication:
- United States
- Language:
- English
Similar Records
Two hemodynamic problems commonly associated with the microsphere technique for measuring regional blood flow in rats
Regional blood flow in the domestic fowl immediately following chronic acceleration
Microsphere reference flow samples during systemic flow adjustment
Journal Article
·
Sun Mar 31 23:00:00 EST 1985
· J. Pharmacol. Methods; (United States)
·
OSTI ID:5520078
Regional blood flow in the domestic fowl immediately following chronic acceleration
Journal Article
·
Thu Jul 01 00:00:00 EDT 1982
· Aviat., Space Environ. Med.; (United States)
·
OSTI ID:6642453
Microsphere reference flow samples during systemic flow adjustment
Journal Article
·
Tue Mar 31 23:00:00 EST 1987
· Am. J. Physiol.; (United States)
·
OSTI ID:5720697