Experimental value of percent variation in root-mean-square ex-core detector signal to the core barrel amplitude scale factor

Journal Article · · Nucl. Technol.; (United States)
OSTI ID:6918880
Ex-core neutron detector and core barrel-mounted accelerometer signals were used to determine the ratio of percent variation in the ex-core signal to core barrel amplitude. Based on these data, the nominal value, includig uncertainties, is 1.60 +- 0.24%/mm (0.0407 +- 0.006%/mil). This result is in agreement with both predictions, based on a one-dimensional transport model, and previously reported data.
Research Organization:
Combustion Engineering, Inc., Windsor, CT
OSTI ID:
6918880
Journal Information:
Nucl. Technol.; (United States), Journal Name: Nucl. Technol.; (United States) Vol. 48:2; ISSN NUTYB
Country of Publication:
United States
Language:
English