Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

H sup minus source and low energy transport for an RFQ preinjector

Conference · · Review of Scientific Instruments; (USA)
OSTI ID:6908282
; ;  [1]
  1. AGS Department, Brookhaven National Laboratory, Upton, New York, 11973 (US)

A radio-frequency quadrupole (RFQ) accelerator has replaced a 750-keV Cockcroft-Walton as the H{sup {minus}} preinjector for the Brookhaven alternating gradient synchrotron. A magnetron surface-plasma source with a circular aperture is used to produce 65--100 mA of H{sup {minus}} at 35 keV with a discharge current of less than 20 A. The symmetry of the beam is maintained in the 2-m transport to the RFQ via the use of magnetic solenoids for focusing. Currents up to 60 mA have been obtained out of the RFQ. A traveling-wave electrostatic chopper in the 35-keV transport line leads to a distortion of the emittance due to space-charge effects.

OSTI ID:
6908282
Report Number(s):
CONF-890703--
Journal Information:
Review of Scientific Instruments; (USA), Journal Name: Review of Scientific Instruments; (USA) Vol. 61:1; ISSN RSINA; ISSN 0034-6748
Country of Publication:
United States
Language:
English