Reliability tests for physical protection systems (II)
Conference
·
· Nucl. Mater. Manage.; (United States)
OSTI ID:6899319
PNC has carried out the reliability tests as a part of its R and D programs on the physical protection systems for its nuclear facilities from 1977 to 1982. The purpose of these tests was to evaluate the effectiveness, reliability and resistance to tampering of various physical protection devices such as intrusion detectors, access control systems, and physical barriers against potential threats. The results obtained from these tests have been used to design effective protection systems to meet current requirements, and simultaneously to establish the physical protection installation standards of Japan. The results of the former tests were presented at the 22nd Annual Meeting; this paper, therefore, will describe the results of the access control systems and the integrated protection system evaluated in 1981-1982. Both the access control systems are new personnel identifications which utilize face verification and height-weight verification. The face verification system in particular is expected to be adopted at PNC facilities in the near future. The model integrated protection system was composed of effective devices selected with due consideration to the results obtained from tests, and the functions of detection, access control, assessment, delay and communication through intrusion and working tests were evaluated.
- Research Organization:
- Power Reactor and Nuclear Fuel Development Corp., Tokyo
- OSTI ID:
- 6899319
- Report Number(s):
- CONF-830709-
- Conference Information:
- Journal Name: Nucl. Mater. Manage.; (United States) Journal Volume: 12
- Country of Publication:
- United States
- Language:
- English
Similar Records
Physical protection philosophy and techniques in Japan
Evaluation of physical-protection elements for interior applications
Protecting high value assets in transit
Journal Article
·
Thu Dec 31 23:00:00 EST 1987
· JNMM; (United States)
·
OSTI ID:6241571
Evaluation of physical-protection elements for interior applications
Conference
·
Fri Dec 31 23:00:00 EST 1982
·
OSTI ID:5975797
Protecting high value assets in transit
Conference
·
Mon Dec 31 23:00:00 EST 1990
· Nuclear Materials Management. Annual Meeting Proceedings; (United States)
·
OSTI ID:5664364
Related Subjects
055001* -- Nuclear Fuels-- Safeguards
Inspection
& Accountability-- Technical Aspects
22 GENERAL STUDIES OF NUCLEAR REACTORS
220900 -- Nuclear Reactor Technology-- Reactor Safety
98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL PROTECTION
CONTROL SYSTEMS
ENTRY CONTROL SYSTEMS
IDENTIFICATION SYSTEMS
JAPANESE ORGANIZATIONS
NATIONAL ORGANIZATIONS
NUCLEAR FACILITIES
PERFORMANCE TESTING
PERSONNEL
PHYSICAL PROTECTION DEVICES
PNC
RELIABILITY
TECHNOLOGY ASSESSMENT
TESTING
TIME DELAY
Inspection
& Accountability-- Technical Aspects
22 GENERAL STUDIES OF NUCLEAR REACTORS
220900 -- Nuclear Reactor Technology-- Reactor Safety
98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL PROTECTION
CONTROL SYSTEMS
ENTRY CONTROL SYSTEMS
IDENTIFICATION SYSTEMS
JAPANESE ORGANIZATIONS
NATIONAL ORGANIZATIONS
NUCLEAR FACILITIES
PERFORMANCE TESTING
PERSONNEL
PHYSICAL PROTECTION DEVICES
PNC
RELIABILITY
TECHNOLOGY ASSESSMENT
TESTING
TIME DELAY