Evaluation of nonazeotropic refrigerant mixtures for capacity modulation
Conference
·
OSTI ID:6882310
A test program is underway at the Oak Ridge National Laboratory (ORNL) to evaluate the potential performance improvements from using nonazeotropic refrigerant mixtures in residential heat pumps. The goals of the research effort are to achieve (1) capacity control by adjusting the composition, (2) increased capacity, relative to R22, at low ambient temperatures, and (3) matching of the refrigerant temperature differentials to the source and sink fluid temperature differentials. Performance improvements are expected to result from decreasing the cycling losses and the amount of resistance heat required at low ambient temperatures along with reducing the irreversibilities in the heat exchangers. Initial results for a mixture of R13B1/R152a show a potential capacity modulation from 12431 Btu/h (3643 W) at 17 F (/minus/8.3/degree/C) to 8550 Btu/h (2506 W) at 47 F (8.3/degree/C) in heating and from 7451 Btu/h (2184 W) at 82 F (27. 8/degree/C) to 9188 Btu/h (2693 W) at 95 F (35/degree/C) in cooling. Other refrigerant pairs which are safer from an ozone depletion standpoint are under consideration for later testing. 10 refs., 5 figs., 4 tabs.
- Research Organization:
- Oak Ridge National Lab., TN (USA)
- DOE Contract Number:
- AC05-84OR21400
- OSTI ID:
- 6882310
- Report Number(s):
- CONF-8804100-3; ON: DE88013244
- Country of Publication:
- United States
- Language:
- English
Similar Records
Laboratory testing of a heat pump system with water-to-water, counterflow heat exchangers using various compositions of an R13B1/R152a nonazeotropic refrigerant mixture
Performance of a conventional residential-sized heat pump operating with a nonazeotropic binary refrigerant mixture
Cycle performance comparison between a nonazeotropic refrigerant mixture and R22
Conference
·
Wed Dec 31 23:00:00 EST 1986
·
OSTI ID:5617108
Performance of a conventional residential-sized heat pump operating with a nonazeotropic binary refrigerant mixture
Technical Report
·
Wed Oct 01 00:00:00 EDT 1986
·
OSTI ID:6611648
Cycle performance comparison between a nonazeotropic refrigerant mixture and R22
Conference
·
Mon Dec 31 23:00:00 EST 1990
·
OSTI ID:5475352
Related Subjects
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION
320106* -- Energy Conservation
Consumption
& Utilization-- Building Equipment-- (1987-)
BUILDINGS
COEFFICIENT OF PERFORMANCE
COOLING SYSTEMS
DATA
DIAGRAMS
ENERGY SYSTEMS
EXPERIMENTAL DATA
FLOWSHEETS
FLUIDS
HEAT EXCHANGERS
HEAT PUMPS
HEATING SYSTEMS
INFORMATION
NUMERICAL DATA
OPTIMIZATION
REFRIGERANTS
RESIDENTIAL BUILDINGS
TESTING
THERMODYNAMICS
WORKING FLUIDS
320106* -- Energy Conservation
Consumption
& Utilization-- Building Equipment-- (1987-)
BUILDINGS
COEFFICIENT OF PERFORMANCE
COOLING SYSTEMS
DATA
DIAGRAMS
ENERGY SYSTEMS
EXPERIMENTAL DATA
FLOWSHEETS
FLUIDS
HEAT EXCHANGERS
HEAT PUMPS
HEATING SYSTEMS
INFORMATION
NUMERICAL DATA
OPTIMIZATION
REFRIGERANTS
RESIDENTIAL BUILDINGS
TESTING
THERMODYNAMICS
WORKING FLUIDS