Woodstove Emission Sampling Methods Comparability Analysis and In-situ Evaluation of New Technology Woodstoves.
One major objective of this study was to compare several woodstove particulate emission sampling methods under laboratory and in-situ conditions. The laboratory work compared the EPA Method 5H, EPA Method 5G, and OMNI Automated Woodstove Emission Sampler (AWES)/Data LOG'r particulate emission sampling systems. A second major objective of the study was to evaluate the performance of two integral catalytic, two low emission non-catalytic, and two conventional technology woodstoves under in-situ conditions with AWES/Data LOG'r system. The AWES/Data LOG'r and EPA Method 5G sampling systems were also compared in an in-situ test on one of the integral catalytic woodstove models. 7 figs., 12 tabs.
- Research Organization:
- Pacific Northwest and Alaska Bioenergy Program (U.S.)
- Sponsoring Organization:
- United States. Bonneville Power Administration.
- DOE Contract Number:
- AC79-85BP18508
- OSTI ID:
- 6879664
- Report Number(s):
- DOE/BP-18508-6; ON: DE89001551
- Country of Publication:
- United States
- Language:
- English
Similar Records
Comparability between various field and laboratory wood-stove emission-measurement methods
Woodstove smoke and CO emissions: Comparison of reference methods with the VIP sampler
Related Subjects
090400* -- Solid Waste & Wood Fuels-- (-1989)
AIR POLLUTION ABATEMENT
AIR QUALITY
APPLIANCES
CHEMICAL REACTION KINETICS
COMBUSTION KINETICS
DATA
ENVIRONMENTAL QUALITY
EVALUATION
EXPERIMENTAL DATA
INFORMATION
KINETICS
NUMERICAL DATA
PARTICLES
PARTICULATES
POLLUTION ABATEMENT
REACTION KINETICS
SAMPLING
Stoves
Wood - Environmental aspects
TESTING