Improved bremsstrahlung radiation uniformity from an indented-anode diode

Journal Article · · Appl. Phys. Lett.; (United States)
DOI:https://doi.org/10.1063/1.98052· OSTI ID:6873733

Use of an indented anode in a cylindrical-cathode, planar anode diode placed at the exit of a coaxial magnetically insulated transmission line on the h-smcapse-smcapsl-smcapsIa-smcaps accelerator results in improved radiation uniformity. Measurements of the uniformity made on the accelerator at 3 MV, 150 kA are compared and shown to agree with theoretical calculations. The advantage of this scheme over that of the planar anode is that the diode impedance, pinch angle, and radial impact position at the anode can be partially decoupled.

Research Organization:
Sandia National Laboratories, Albuquerque, New Mexico 87185
OSTI ID:
6873733
Journal Information:
Appl. Phys. Lett.; (United States), Journal Name: Appl. Phys. Lett.; (United States) Vol. 50:13; ISSN APPLA
Country of Publication:
United States
Language:
English

Similar Records

Theoretical motivation of indented-anode diode for HERMES III
Technical Report · Wed Dec 31 23:00:00 EST 1986 · OSTI ID:6850847

Impedance of an annular-cathode indented-anode electron diode terminating a coaxial magnetically insulated transmission line
Journal Article · Sun Jan 31 23:00:00 EST 1988 · J. Appl. Phys.; (United States) · OSTI ID:5657740

Improved flash. gamma. -ray uniformity using a B/sub theta/ lens diode
Journal Article · Mon Apr 10 00:00:00 EDT 1989 · Appl. Phys. Lett.; (United States) · OSTI ID:6456971