Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Design of integral shutters for the beamlines at the Advanced Photon Source

Journal Article · · Review of Scientific Instruments; (United States)
DOI:https://doi.org/10.1063/1.1145872· OSTI ID:6865086
; ; ; ;  [1]
  1. Argonne National Laboratory, Advanced Photon Source, Argonne, Illinois 60439 (United States)
An integral shutter is a device that integrates a white-beam stop, monochromatic-beam (mono-beam) shutters, a safety stop, and a collimator into one assembly to save space in the photon beamline. Various integral shutters have been developed as standard components for the beamlines at the advanced photon source. The integral shutters are designed to be operated in white-beam mode or mono-beam mode. With regard to safety, each mode of operation is secured by locking certain devices in their up or down positions. Some of the components of the integral shutters share designs similar to the front-end shutters or fixed masks. Design details of the integral shutters are presented.
Research Organization:
Argonne National Laboratory (ANL), Argonne, IL
DOE Contract Number:
W-31109-ENG-38
OSTI ID:
6865086
Journal Information:
Review of Scientific Instruments; (United States), Journal Name: Review of Scientific Instruments; (United States) Vol. 66:2; ISSN 0034-6748; ISSN RSINAK
Country of Publication:
United States
Language:
English