[PFBC Hot Gas Cleanup Test Program]

Technical Report ·
DOI:https://doi.org/10.2172/6864073· OSTI ID:6864073

Four hundred and fifty four clay bonded silicon carbide Schumacher Dia Schumalith candle filters were purchased for installation in the Westinghouse Advanced Particle Filtration (APF) system at the American Electric Power (AEP) plant in Brilliant, Ohio. A surveillance effort has been identified which will monitor candle filter performance and life during hot gas cleaning in AEP's pressurized fluidized-bed combustion system. A description of the candle surveillance program, strategy for candle filter location selection, as well as candle filter post-test characterization is provided in this memo. The period of effort for candle filter surveillance monitoring is planned through March 1994.

Research Organization:
American Electric Power Service Corp., Columbus, OH (United States)
Sponsoring Organization:
DOE; USDOE, Washington, DC (United States)
DOE Contract Number:
FC21-89MC26042
OSTI ID:
6864073
Report Number(s):
DOE/MC/26042-3222; ON: DE93012801
Country of Publication:
United States
Language:
English