AC loss comparison of NbTi-Cu and NbTi-Cu-CuNi superconducting composite magnets

Journal Article · · Chin. Phys.; (United States)
OSTI ID:6862085

AC losses of NbTi-Cu and NbTi-Cu-CuNi superconducting composite magnets have been measured by means of an electronic integration technique. The experimental results are presented and their qualitative comparisons are made. It is shown within our experimental range that: (1) AC losses of NbTi-Cu composite magnet are proportional to the peak value and exciting velocity of the magnetic field; and (2) AC losses of NbTi-Cu-CuNi composite magnet are also proportional to the peak value of the magnetic field, but decrease as exciting velocity increases.