A compilation of operating problems and equipment failures affecting the operability and safety of evaporators in the Savannah River Plant H-Canyon facility is presented. These data have been collected over the 28-year operation of this reprocessing area. Data have been sorted by a variety of categories to facilitate usage. A brief description of the evaporators and the data bank from which the information was sorted is also included. 4 references, 2 figures, 3 tables.