Quality factors for monoenergetic neutrons

Journal Article · · Radiat. Res.; (United States)
DOI:https://doi.org/10.2307/3576441· OSTI ID:6855087

Mean quality factors anti Q(E/sub n/), for the dose resulting from first interactons of monoenergetic neutrons in tissue, have been calculated at energies from thermal to 14.7 MeV. Knowledge of these values, along with kerma factors, allows the calculation of the heavy-particle dose equivalent for any known neutron spectrum in tissue. The partial quality factors for the dose delivered by C, N, and O elastic and inelastic recoils are found to be virtually independent of the scattering angular distributions and are given by simple expressions.

Research Organization:
Chalk River Nuclear Laboratories, Ontario
OSTI ID:
6855087
Journal Information:
Radiat. Res.; (United States), Journal Name: Radiat. Res.; (United States) Vol. 99:1; ISSN RAREA
Country of Publication:
United States
Language: