Position-sensitive fission counter for in-core flux profile monitoring

Conference · · IEEE Trans. Nucl. Sci.; (United States)
OSTI ID:6837220
A prototype model of a position-sensitive fission counter (PSFC) was developed for power-range flux profile monitoring in light-water reactor cores. The flux profile is measured by delay-line position encoding and time interval decoding of individual fission pulses from 11 small fission counters incorporated along a coaxial transmission line. Significant improvements over currently used flux profile monitors are the 33-cm spatial resolution of the 3.5-m-long PSFC and the requirement for only one cable penetration into the reactor pressure vessel.
Research Organization:
Instrumentation and Controls Division Oak Ridge National Laboratory Oak Ridge, Tennessee 37831, USA
DOE Contract Number:
W-7405-ENG-26
OSTI ID:
6837220
Report Number(s):
CONF-831015-
Conference Information:
Journal Name: IEEE Trans. Nucl. Sci.; (United States) Journal Volume: 31:1
Country of Publication:
United States
Language:
English