Experimenting with sodar in support of emergency preparedness at Three Mile Island-1

Conference · · Transactions of the American Nuclear Society; (USA)
OSTI ID:6835351
In November 1988 at Three Mile Island Unit 1 (TMI-1), GPU Nuclear successfully completed the annual drill-for-grade that, from a modeling point of view, broke new ground for this plant. The meteorological and modeling aspects of the drill scenario were unprecedented for two reasons. First, the plume was buoyant and rose far above the height of the meteorological tower located at TMI. Second, the wind direction data from the meteorological tower were not representative of the wind direction at plume height. In the drill scenario, the buoyant plume resulted from a steam generator tube rupture where the steam ejects directly into the atmosphere via safety relief valves. Plume modeling indicated that the plume would rise to 400 ft, given the scenario meteorology. Wind data from the on-site meteorological tower, however, was only available up to 150 ft. Comparisons of sodar and tower winds were made for various weather conditions. Sodar results were studied in detail during light, moderate, and high winds; various wind directions; occurrences of rain and snow; and by time of day to determine effects of diurnal meteorological conditions on sodar performance.
OSTI ID:
6835351
Report Number(s):
CONF-891103--
Conference Information:
Journal Name: Transactions of the American Nuclear Society; (USA) Journal Volume: 60
Country of Publication:
United States
Language:
English