Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Nonradiometric and radiometric testing of radioiodine sorbents using methyl iodide

Conference ·
OSTI ID:6833939
A nonradiometric test of adsorbents and adsorbers with normal methyl iodide (CH/sub 3//sup 127/I) is desirable. Use of methyl radioiodide (CH/sub 3//sup 131/I) requires special precautions and facilities and results in bed contamination. However, first it must be established to what extent the removal of CH/sub 3//sup 127/I by adsorbents is indicative of the removal of CH/sub 3//sup 131/I. An experimental apparatus was built and used to simultaneously measure the penetrations of CH/sub 3/I molecules and the radioisotope in CH/sub 3//sup 131/I through charcoal absorbent beds. Gas chromatography with electron capture detection was used to measure CH/sub 3/I. Radioiodine was measured using charcoal traps within NaI scintillation well crystals. Real time (5-min interval) radioiodine measurement provided immediate penetration results directly comparable to the real time penetrations of methyl iodide. These penetrations were compared for typical charcoal adsorbents with these impregnants: (a) 5% KI/sub 3/, (b) 5% KI/sub 3/ + 2% TEDA, (c) 5% TEDA, and (d) metal salts (Whetlerite). Differences between CH/sub 3/I and CH/sub 3//sup 131/I penetrations observed for the two iodized charcoals were attributed to isotope exchange reactions. Equivalent penetrations were observed for non-iodized adsorbents and for iodized ones at initial time. First order rates were confirmed for reactions with TEDA and for isotope exchange. This was one more confirmation of the lack of a challenge concentration effect on efficiencies at low test bed loadings. In addition to other removal mechanisms, reversible physical adsorption was observed with all charcoals.
Research Organization:
Los Alamos Scientific Lab., NM (USA)
DOE Contract Number:
W-7405-ENG-36
OSTI ID:
6833939
Report Number(s):
LA-UR-80-2864; CONF-801038-12
Country of Publication:
United States
Language:
English

Similar Records

Testing iodized activated carbon filters with non-radioactive methyl iodide. Final report
Technical Report · Fri May 30 00:00:00 EDT 1980 · OSTI ID:6429756

Respirator canister testing for radioiodine
Journal Article · Sat Aug 01 00:00:00 EDT 1981 · Am. Ind. Hyg. Assoc. J.; (United States) · OSTI ID:6039948

Desorption of TEDA from impregnated charcoals
Conference · Mon Dec 31 23:00:00 EST 1979 · OSTI ID:6767023