Evaluation of horizontal cooling channels for actively cooled limiters

Conference · · Fusion Technol.; (United States)
OSTI ID:6832420

The heat flux and fluid flow conditions for a water cooled limiter tube are simulated with an electron beam heating apparatus, and the results are compared to empirical models based on existing heating transfer correlations. For the conditions of highly subcooled flow boiling in a horizontal tube subjected to a heat flux from only one side, two principal observations were noted. First, existing heat flux correlations, which were developed for use with uniform circumferential heat flux distributions, can be used to provide a good first approximation of the one-sided heat removal for the range of experimental conditions covered. Second, the peak heat flux at the tube surface predicts the onset of critical heat flux (burnout) better than the average heat flux.

Research Organization:
Sandia National Labs., Albuquerque, NM 87185
DOE Contract Number:
AC04-76DP00789
OSTI ID:
6832420
Report Number(s):
CONF-860652-
Journal Information:
Fusion Technol.; (United States), Journal Name: Fusion Technol.; (United States) Vol. 10:3; ISSN FUSTE
Country of Publication:
United States
Language:
English