Results from the SLD barrel CRID detector

Conference · · IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (United States)
OSTI ID:6815548
 [1];  [2];  [3]
  1. Tohoku Univ., Sendai (Japan). Dept. of Physics
  2. Stanford Linear Accelerator Center, Stanford, CA (United States) Colorado State Univ., Fort Collins, CO (United States). Dept. of Physics
  3. Stanford Linear Accelerator Center, CA (United States); and others
The SLD barrel Cherenkov Ring Imaging Detector (CRID) has been in full operation for two years at the SLAC Linear Collider. The authors report on operational experience with and experimental performance of the SLD barrel Cherenkov Ring Imaging Detector from the 1992 and 1993 physics runs. The liquid (C[sub 6]F[sub 14]) and gas (C[sub 5]F[sub 12]) radiator recirculation system shave performed well, and the drift gas supply system has operated successfully with TMAE for three years. Cherenkov rings have been observed from both the liquid and gas radiators. The number and angular resolution of Cherenkov photons have been measured, and found to be close to design specification.
DOE Contract Number:
AC03-76SF00515
OSTI ID:
6815548
Report Number(s):
CONF-931051--
Conference Information:
Journal Name: IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (United States) Journal Volume: 41:4Pt1
Country of Publication:
United States
Language:
English