Heating energy measurements of single-family houses with attics containing radiant barriers in combustion with R-11 and R-30 ceiling insulation
Technical Report
·
OSTI ID:6813025
Tests were conducted by Oak Ridge National Laboratory to determine the heating energy performance of two levels of fiberglass-batt attic insulation (R-11 and R-30) in combination with truss and horizontally installed radiant barriers. The tests, a continuation of work started in the summer of 1985, were conducted in three unoccupied ranch-style houses in Karns, Tennessee, during the winter of 1986-87. The measured results of the heating tests showed that a horizontal radiant barrier used with R-11 attic insulation reduced the house heating load by 9.3% compared with R-11 with no radiant barrier, while a truss barrier showed essentially no change in the heating load. Horizontal and truss barriers each reduced the heating load by 3.5% when added to R-30 attic insulation. Moisture condensed on the bottom of the horizontal barrier during cold early morning weather but usually dissipated in the warmer afternoon hours at Karns and left no accumulation in the insulation. Depending on the level of attic insulation, an annual heating and cooling HVAC savings ranging from $5 to $65 is estimated to be attainable when a radiant barrier is installed in the attic at Karns. 8 refs., 64 figs., 18 tabs.
- Research Organization:
- Oak Ridge National Lab., TN (USA)
- DOE Contract Number:
- AC05-84OR21400
- OSTI ID:
- 6813025
- Report Number(s):
- ORNL/CON-239; ON: DE89001304
- Country of Publication:
- United States
- Language:
- English
Similar Records
Cooling energy measurements of single-family houses with attics containing radiant barriers in combination with R-11 and R-30 ceiling insulation
Energy measurements of single-family houses with attics containing radiant barriers
Energy measurements of single-family houses with attics containing radiant barriers
Technical Report
·
Fri May 01 00:00:00 EDT 1987
·
OSTI ID:6171133
Energy measurements of single-family houses with attics containing radiant barriers
Conference
·
Mon Jun 01 00:00:00 EDT 1987
· ASHRAE Trans.; (United States)
·
OSTI ID:6424763
Energy measurements of single-family houses with attics containing radiant barriers
Conference
·
Wed Dec 31 23:00:00 EST 1986
·
OSTI ID:6637515
Related Subjects
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION
320100* -- Energy Conservation
Consumption
& Utilization-- Buildings
ATTICS
BUILDING MATERIALS
BUILDINGS
COST
DATA
ENERGY CONSERVATION
HEATING
HOUSES
INFORMATION
MATERIALS
NUMERICAL DATA
PERFORMANCE
R FACTORS
RESIDENTIAL BUILDINGS
THERMAL INSULATION
WEATHERIZATION
320100* -- Energy Conservation
Consumption
& Utilization-- Buildings
ATTICS
BUILDING MATERIALS
BUILDINGS
COST
DATA
ENERGY CONSERVATION
HEATING
HOUSES
INFORMATION
MATERIALS
NUMERICAL DATA
PERFORMANCE
R FACTORS
RESIDENTIAL BUILDINGS
THERMAL INSULATION
WEATHERIZATION