Galvanic currents and hydrogen permeation currents caused by galvanic coupling

Journal Article · · Corrosion (Houston); (USA)
DOI:https://doi.org/10.5006/1.3585117· OSTI ID:6794264
 [1];  [2]
  1. Corrosion Research Center, Univ. of Minnesota, Minneapolis, MN (US)
  2. Rosemount Inc., Eden Prarie, MN (US)

This paper reports on galvanic coupling and hydrogen permeation experiments performed in a Devanathan-Stachurski cell to measure simultaneously the galvanic currents and the hydrogen permeation currents in an attempt to determine the extent of hydrogen charging into noble metals as a result of galvanic coupling. Large amounts of hydrogen permeated through the more noble element of the couple. The magnitude of the hydrogen permeation flux varied depending on the galvanic coupling conditions. No simple direct relationship between galvanic currents and hydrogen permeation currents was observed, although large hydrogen permeation currents were usually developed whenever large galvanic currents were established.