Management of coal waste by energy recovery: mild gasification/flash pyrolysis of coal preparation wastes. Quarterly report, January-March 1986

Technical Report ·
OSTI ID:6793340

Construction continued on the Mild Gasification Unit, MGU, with the addition of the vacuum pump. The MGU can now be operated under vacuum conditions. Modifications were made to the reactor tube packing box after leaks were discovered around the old packing boxes. The new packing box is taller and wider than the old packing box allowing more effective packing. Preliminary testing shows a good vacuum seal is obtained with the modified packing box. Eight tests were conducted on the MGU. Each of the eight tests were considered a shakedown test. A variety of reactor tube configurations, condensing systems, and operating conditions were tested. It was found that operating under vacuum conditions improved the quality of liquids. Also, it was found that coal residence times can be significantly reduced by operating at increased furnace temperatures. The MGU has performed well with no major problems. The only significant problem encountered to date has been effective condensation of the hydrocarbon gases. Continuing efforts are being made toward improving the condensation system on the MGU.

Research Organization:
UCC Research Corp., Bristol, VA (USA)
DOE Contract Number:
AC21-84MC21108
OSTI ID:
6793340
Report Number(s):
DOE/MC/21108-T2; ON: DE86012727
Country of Publication:
United States
Language:
English