Libbey--Owens--Ford Solar Collector static load test
The results of the static load test which was performed on the Libbey--Owens--Ford Solar Collector are presented. The test article is a flat-plate solar collector that uses liquid as the heat transfer medium. The overall dimensions of the collector are 3' x 7' x 4-3/4''. The absorber plate is No. 110 copper and is .021'' thick. It has a double glass cover of 1/8'' tempered glass and weighs approximately 130 pounds.
- Research Organization:
- Wyle Labs., Huntsville, AL (USA). Solar Energy Systems Div.