This report describes the test site, equipment, and procedures and presents the data obtained during field testing at Texas Utilities DeCordova Steam Electric Station, June 3-8, 1997. This was the first of three field tests that the US Environmental Protection Agency (EPA) conducted in 1997 as part of a major study to evaluate potential improvements to Method 2, EPA`s test Method for measuring flue gas volumetric flow in stacks. The report also includes a Data Distribution Package, the official, complete repository of the results obtained at this test site.
- Research Organization:
- Cadmus Group, Inc., Durham, NC (United States); Environmental Protection Agency, Acid Rain Div., Washington, DC (United States)
- Sponsoring Organization:
- Environmental Protection Agency, Washington, DC (United States)
- OSTI ID:
- 678930
- Report Number(s):
- PB-99-150401/XAB; TRN: 99:009301
- Resource Relation:
- Other Information: DN: See also PB99-150310, PB99-150328, PB99-150336, PB99-150286, PB99-150294, PB99-150385 and PB99-150369. See electronic version on disk PB99-150393.; PBD: Sep 1998
- Country of Publication:
- United States
- Language:
- English
Similar Records
EPA flow reference method testing and analysis: Data report -- Texas Utilities, Lake Hubbard Steam Electric Station. Volume 1: Test description and appendix A (data distribution package)
EPA flow reference method testing and analysis: Data report -- Pennsylvania Electric Company, G.P.U. Genco Homer City Station. Volume 1: Test description and appendix A (data distribution package)
Flow reference method testing and analysis: Field test plan, Texas Utilities Decordova Steam Electric Station
Technical Report
·
Tue Sep 01 00:00:00 EDT 1998
·
OSTI ID:678930
EPA flow reference method testing and analysis: Data report -- Pennsylvania Electric Company, G.P.U. Genco Homer City Station. Volume 1: Test description and appendix A (data distribution package)
Technical Report
·
Tue Sep 01 00:00:00 EDT 1998
·
OSTI ID:678930
Flow reference method testing and analysis: Field test plan, Texas Utilities Decordova Steam Electric Station
Technical Report
·
Fri May 30 00:00:00 EDT 1997
·
OSTI ID:678930