Computed tomographic scanning in children: comparison of radiation dose and resolving power of commercial CT scanners
Conference
·
· Am. J. Roentgenol.; (United States)
OSTI ID:6788180
Surface and internal radiation doses for abdominal computed tomography (CT) of children were determined using child-sized phantoms and seven models of CT body scanners. Resolving power of each scanner was determined simultaneously with the radiation dose determination. The average surface skin dose for a complete CT body examination ranged from 0.39 to 5.60 rad, varying with patient size and model of CT scanner employed. A high contrast (12%) resolving power phantom of water-filled holes in acrylic showed a range of 1.75 to 2.25 mm.
- Research Organization:
- Univ. of California, San Francisco
- OSTI ID:
- 6788180
- Journal Information:
- Am. J. Roentgenol.; (United States), Vol. 131:1; Conference: Annual meeting of the Society for Pediatric Radiology, Boston, MA, USA, Sep 1977
- Country of Publication:
- United States
- Language:
- English
Similar Records
Computed tomographic scanning in children. II. An updated comparison of radiation dose and resolving power of commercial scanners
SU-F-I-32: Organ Doses from Pediatric Head CT Scan
Evaluation of radiation dose and image quality of CT scan for whole-body pediatric PET/CT: A phantom study
Journal Article
·
Fri Jan 01 00:00:00 EST 1982
· AJR, Am. J. Roentgenol.; (United States)
·
OSTI ID:6788180
SU-F-I-32: Organ Doses from Pediatric Head CT Scan
Journal Article
·
Wed Jun 15 00:00:00 EDT 2016
· Medical Physics
·
OSTI ID:6788180
+5 more
Evaluation of radiation dose and image quality of CT scan for whole-body pediatric PET/CT: A phantom study
Journal Article
·
Mon Sep 15 00:00:00 EDT 2014
· Medical Physics
·
OSTI ID:6788180
+1 more
Related Subjects
63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTANT EFFECTS ON LIVING ORGS. AND BIOL. MAT.
62 RADIOLOGY AND NUCLEAR MEDICINE
47 OTHER INSTRUMENTATION
CAT SCANNING
RADIATION DOSES
CHILDREN
IMAGE SCANNERS
SPATIAL RESOLUTION
COMPARATIVE EVALUATIONS
CORRELATIONS
PATIENTS
PHANTOMS
THERMOLUMINESCENT DOSEMETERS
ANIMALS
DIAGNOSTIC TECHNIQUES
DOSEMETERS
DOSES
LUMINESCENT DOSEMETERS
MAMMALS
MAN
MEASURING INSTRUMENTS
MOCKUP
PHOTON TRANSMISSION SCANNING
PRIMATES
RESOLUTION
STRUCTURAL MODELS
VERTEBRATES
560151* - Radiation Effects on Animals- Man
550600 - Medicine
440300 - Miscellaneous Instruments- (-1989)
62 RADIOLOGY AND NUCLEAR MEDICINE
47 OTHER INSTRUMENTATION
CAT SCANNING
RADIATION DOSES
CHILDREN
IMAGE SCANNERS
SPATIAL RESOLUTION
COMPARATIVE EVALUATIONS
CORRELATIONS
PATIENTS
PHANTOMS
THERMOLUMINESCENT DOSEMETERS
ANIMALS
DIAGNOSTIC TECHNIQUES
DOSEMETERS
DOSES
LUMINESCENT DOSEMETERS
MAMMALS
MAN
MEASURING INSTRUMENTS
MOCKUP
PHOTON TRANSMISSION SCANNING
PRIMATES
RESOLUTION
STRUCTURAL MODELS
VERTEBRATES
560151* - Radiation Effects on Animals- Man
550600 - Medicine
440300 - Miscellaneous Instruments- (-1989)