Multigated blood-pool tomography: new method for the assessment of left ventricular function
Journal Article
·
· J. Nucl. Med.; (United States)
OSTI ID:6782204
A technique for the semiautomatic calculation of left ventricular volumes from multigated blood-pool tomograms (MGBPT) was tested in a series of 12 patients undergoing contrast ventriculography within 48 hr of gated tomography. The parameters necessary for the calculation of volume were developed in a chest phantom study performed with a series of /sup 99m/Tc-filled balloons representing the right and left ventricles. The images were analyzed for volume using a percentage of peak count-threshold of the left ventricular balloon. This technique resulted in a correlation of r = 0.99 of the calculated to the true phantom volumes (y = 0.87x + 27.4, p less than 0.01, s.e.e. = 7.87 ml). The patient studies were recorded at 16 frames/cardiac cycle at each of 60 angles over a 360 degree rotation. Reconstructed data were presented in an endless loop cine format producing a set of sequential beating tomographic slices in the transverse, apical four-chamber, short-axis, and long-axis oblique views. Measurements of end systolic volume (y = 0.79x + 30, r = 0.93, p less than 0.001, s.e.e. = 24 ml), end-diastolic volume (y = 0.63x + 60, r = 0.94, p less than 0.0001, s.e.e. = 20 ml) and ejection fraction (y = 0.88x - 0.02, r = 0.92, p less than 0.001, s.e.e. = 0.08) determined from the semiautomated volume method correlated well with those determined by left ventricular contrast angiography. A qualitative comparison of MGBPT, planar imaging, and left ventricular angiography in 12 patients revealed that the visual assessment of wall motion using the 16-frame tomographic slices had significant advantages over planar and single plane angiographic data in the identification of inferior, basal, and septal wall motion abnormalities as well as the extent of involvement by aneurysm formation.
- Research Organization:
- Massachusetts General Hospital, Boston
- OSTI ID:
- 6782204
- Journal Information:
- J. Nucl. Med.; (United States), Journal Name: J. Nucl. Med.; (United States) Vol. 12; ISSN JNMEA
- Country of Publication:
- United States
- Language:
- English
Similar Records
Estimation of left ventricular mass in normal and infarcted canine hearts using thallium-201 SPECT
A dual collimator design for beat-to-beat measurement of cardiac performance with an Anger camera
Blood pool tomography: Evaluation of left ventricular volumes and regional wall motion
Journal Article
·
Sat Aug 01 00:00:00 EDT 1987
· J. Nucl. Med.; (United States)
·
OSTI ID:6178410
A dual collimator design for beat-to-beat measurement of cardiac performance with an Anger camera
Journal Article
·
Wed Sep 01 00:00:00 EDT 1982
· J. Nucl. Med.; (United States)
·
OSTI ID:6705649
Blood pool tomography: Evaluation of left ventricular volumes and regional wall motion
Conference
·
Wed May 01 00:00:00 EDT 1985
· J. Nucl. Med.; (United States)
·
OSTI ID:5971445
Related Subjects
550601* -- Medicine-- Unsealed Radionuclides in Diagnostics
62 RADIOLOGY AND NUCLEAR MEDICINE
BETA DECAY RADIOISOTOPES
BETA-MINUS DECAY RADIOISOTOPES
BODY
CARDIOVASCULAR SYSTEM
DIAGNOSTIC TECHNIQUES
DYNAMIC FUNCTION STUDIES
HEART
HOURS LIVING RADIOISOTOPES
INTERMEDIATE MASS NUCLEI
ISOMERIC TRANSITION ISOTOPES
ISOTOPES
MOCKUP
NUCLEI
ODD-EVEN NUCLEI
ORGANS
PATIENTS
PHANTOMS
RADIOISOTOPES
STRUCTURAL MODELS
TECHNETIUM 99
TECHNETIUM ISOTOPES
TOMOGRAPHY
YEARS LIVING RADIOISOTOPES
62 RADIOLOGY AND NUCLEAR MEDICINE
BETA DECAY RADIOISOTOPES
BETA-MINUS DECAY RADIOISOTOPES
BODY
CARDIOVASCULAR SYSTEM
DIAGNOSTIC TECHNIQUES
DYNAMIC FUNCTION STUDIES
HEART
HOURS LIVING RADIOISOTOPES
INTERMEDIATE MASS NUCLEI
ISOMERIC TRANSITION ISOTOPES
ISOTOPES
MOCKUP
NUCLEI
ODD-EVEN NUCLEI
ORGANS
PATIENTS
PHANTOMS
RADIOISOTOPES
STRUCTURAL MODELS
TECHNETIUM 99
TECHNETIUM ISOTOPES
TOMOGRAPHY
YEARS LIVING RADIOISOTOPES