A calibration phantom for absolute quantitation of radionuclide uptake by SPECT
Conference
·
· J. Nucl. Med.; (United States)
OSTI ID:6779943
Absolute quantitation of radionuclide uptake in small volumes or organs is of interest for nuclear medicine procedures including the estimation of radiation dose in radioimmunotherapy. The use of a calibration phantom for absolute quantitation of a radionuclide in small volumes in a transverse section image of a SPECT phantom with a rotating gamma camera has been investigated. The calibration phantom is a set of 4 tubes filled with a suitable range of specific activity of the radionuclide in solution. This is scanned simultaneously with the SPECT phantom or patient. The tubes can either be placed at appropriate points on the patient boundary or enclosed in a tissue equivalent crescent-shaped phantom which is either attached to the underside of the SPECT table or placed on the patient to preserve the ellipse for attenuation compensation. A region of interest (ROI) for each tube and volume in the transverse section image was defined with an appropriate threshold of about 10% and the variation of counts in the ROI versus specific activity was found to be linear over the range 1 to 100..mu..Ciml/sup -1/. However, the counts from the calibration phantom were found to depend on the total activity in the transverse section slice, the size and effective attenuation coefficient of the transverse section, the reconstruction filter used and the accuracy of boundary detection for attenuation compensation. Preliminary results indicate that this SPECT calibration phantom can be used for absolute quantitation of radionuclide uptake in a selected site in the body, provided attenuation compensation is satisfactory. Also, the method will simplify determination of cumulated activity for radiation dose calculations.
- Research Organization:
- Univ. of California Davis Medical Center, Sacramento, CA
- OSTI ID:
- 6779943
- Report Number(s):
- CONF-840619-
- Conference Information:
- Journal Name: J. Nucl. Med.; (United States) Journal Volume: 25:5
- Country of Publication:
- United States
- Language:
- English
Similar Records
Development of a SPECT-based 3-D methodology for internal dosimetry of radioimmunotherapy
Comparison of three boundary detector methods for SPECT
SU-F-J-08: Quantitative SPECT Imaging of Ra-223 in a Phantom
Journal Article
·
Sun May 01 00:00:00 EDT 1994
· Journal of Nuclear Medicine
·
OSTI ID:197990
Comparison of three boundary detector methods for SPECT
Conference
·
Wed May 01 00:00:00 EDT 1985
· J. Nucl. Med.; (United States)
·
OSTI ID:6795157
SU-F-J-08: Quantitative SPECT Imaging of Ra-223 in a Phantom
Journal Article
·
Wed Jun 15 00:00:00 EDT 2016
· Medical Physics
·
OSTI ID:22632144
Related Subjects
550602* -- Medicine-- External Radiation in Diagnostics-- (1980-)
62 RADIOLOGY AND NUCLEAR MEDICINE
ATTENUATION
CALCULATION METHODS
CALIBRATION
COMPUTERIZED TOMOGRAPHY
DIAGNOSTIC TECHNIQUES
DISPERSIONS
EMISSION COMPUTED TOMOGRAPHY
FILTERS
IMAGES
ISOTOPES
MEDICINE
MIXTURES
MOCKUP
NUCLEAR MEDICINE
OPTICAL FILTERS
PATIENTS
PHANTOMS
RADIOISOTOPES
RADIOLOGY
RADIOTHERAPY
SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY
SOLUTIONS
STRUCTURAL MODELS
THERAPY
TOMOGRAPHY
UPTAKE
VOLUME
62 RADIOLOGY AND NUCLEAR MEDICINE
ATTENUATION
CALCULATION METHODS
CALIBRATION
COMPUTERIZED TOMOGRAPHY
DIAGNOSTIC TECHNIQUES
DISPERSIONS
EMISSION COMPUTED TOMOGRAPHY
FILTERS
IMAGES
ISOTOPES
MEDICINE
MIXTURES
MOCKUP
NUCLEAR MEDICINE
OPTICAL FILTERS
PATIENTS
PHANTOMS
RADIOISOTOPES
RADIOLOGY
RADIOTHERAPY
SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY
SOLUTIONS
STRUCTURAL MODELS
THERAPY
TOMOGRAPHY
UPTAKE
VOLUME