The energy saving potential of precooling incoming outdoor air by indirect evaporative cooling
Conference
·
OSTI ID:6777032
This paper investigates the energy saving potentials of using indirect evaporative coolers to precool incoming outdoor air as the first stage of a standard cooling system. For dry and moderately humid locations, either exhaust room air or outdoor air can be used as the secondary air to the indirect evaporative precooler with similar energy savings. Under these conditions, the use of outdoor air is recommended due to the simplicity in installing the duct system. For humid locations, the use of exhaust room air is recommended because the precooling capacity and energy savings will be greatly increased. For locations with short cooling seasons, the use of indirect evaporative coolers for precooling may not be worthwhile. The paper also gives some simplified indices for easily predicting the precooling capacity, energy savings and water consumption of an indirect evaporative precooler. These indices can be used for cooling systems with continuous operation, but further work is needed to determine whether the same indices are also suitable for cooling systems with intermittent operations.
- Research Organization:
- Lawrence Berkeley Lab., CA (United States)
- Sponsoring Organization:
- DOE; USDOE, Washington, DC (United States)
- DOE Contract Number:
- AC03-76SF00098
- OSTI ID:
- 6777032
- Report Number(s):
- LBL-32517; CONF-930118--3; ON: DE93004773
- Country of Publication:
- United States
- Language:
- English
Similar Records
The energy saving potential of precooling incoming outdoor air by indirect evaporative cooling
Energy savings from indirect evaporative pre-cooling: Control strategies and commissioning
Analysis of crossflow indirect evaporative air conditioner
Conference
·
Tue Sep 01 00:00:00 EDT 1992
·
OSTI ID:10116977
Energy savings from indirect evaporative pre-cooling: Control strategies and commissioning
Conference
·
Wed Jul 01 00:00:00 EDT 1998
·
OSTI ID:20006322
Analysis of crossflow indirect evaporative air conditioner
Thesis/Dissertation
·
Fri Dec 31 23:00:00 EST 1982
·
OSTI ID:6890659
Related Subjects
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION
320105 -- Energy Conservation
Consumption
& Utilization-- Building Services-- (1987-)
320106* -- Energy Conservation
Consumption
& Utilization-- Building Equipment-- (1987-)
AIR CONDITIONING
AIR POLLUTION ABATEMENT
ANALYTICAL SOLUTION
COOLING
COOLING SYSTEMS
COST BENEFIT ANALYSIS
ECONOMIC ANALYSIS
ECONOMICS
ENERGY CONSERVATION
EVALUATION
EVAPORATIVE COOLING
HUMIDITY
POLLUTION ABATEMENT
REFRIGERATION
320105 -- Energy Conservation
Consumption
& Utilization-- Building Services-- (1987-)
320106* -- Energy Conservation
Consumption
& Utilization-- Building Equipment-- (1987-)
AIR CONDITIONING
AIR POLLUTION ABATEMENT
ANALYTICAL SOLUTION
COOLING
COOLING SYSTEMS
COST BENEFIT ANALYSIS
ECONOMIC ANALYSIS
ECONOMICS
ENERGY CONSERVATION
EVALUATION
EVAPORATIVE COOLING
HUMIDITY
POLLUTION ABATEMENT
REFRIGERATION