This paper discusses the use of fault tree analysis to identify those areas of nuclear fuel cycle facilities which must be protected to prevent acts of sabotage that could lead to sifnificant release of radioactive material. By proper manipulation of the fault trees for a plant, an analyst can identify vital areas in a manner consistent with regulatory definitions. This paper discusses the general procedures used in the analysis of any nuclear facility. In addition, a structured, generic approach to the development of the fault trees for nuclear power reactors is presented along with selected results of the application of the generic approach to several plants.

Research Organization:
Sandia Labs., Albuquerque, N.Mex. (USA)
DOE Contract Number:
EY-76-C-04-0789
OSTI ID:
6773598
Report Number(s):
SAND-78-1206C
Country of Publication:
United States
Language:
English