Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Wake Studies at the Flowind Vertical Axis Wind Turbine Generator Site.

Technical Report ·
OSTI ID:6761595
In a continuing effort to study and characterize various types and sizes of wind turbine generator wakes a test program was conducted at the FloWind 170 kW vertical axis wind turbine (VAWT) near Ellensburg, Washington. Oregon State University (OSU) scientists measured the wake behind the 90 ft. tall Darrieus VAWT using fixed place and portable kite anemometers. Downwind velocity deficits were measured from 3-9 diameters along the wake centerline at rotor midpoint (55 ft.) and perpendicular to the wake. Wake turbulence characteristics were also measured. The measured velocity deficits were compared to wake model calculations.
Research Organization:
Oregon State Univ., Corvallis (USA). Dept. of Atmospheric Science
Sponsoring Organization:
United States. Bonneville Power Administration. Engineering and Construction Division.
DOE Contract Number:
AC79-81BP29182
OSTI ID:
6761595
Report Number(s):
DOE/BP-232; ON: DE84014837
Country of Publication:
United States
Language:
English