Tests of types 51A and 51M steam generators at Bugey 4 and Tricastin 1 nuclear power plants. Final report

Technical Report ·
OSTI ID:6758352
Following some incidents on a number of US steam generators (SGs), alterations were made to the Westinghouse SGs of series 51 installed on the EDF 900 MW units. To check the merits of these alterations and to better understand the operation of this equipment, a series of tests were run on SG No. 14 of Bugey 4 and No. 20 of Tricastin 1 nuclear units. The tests results are described.
Research Organization:
Electricite de France, 93 - Saint-Denis
OSTI ID:
6758352
Report Number(s):
EPRI-NP-2689; ON: DE83900524
Country of Publication:
United States
Language:
English