Title: Lime-spray-dryer flue-gas desulfurization computer model user's manual. Final report, January 1982-April 1986

Technical Report ·
OSTI ID:6755078

This report describes a lime-spray-dryer/baghouse (FORTRAN) computer model that simulates SO/sub 2/ removal and permits study of related impacts on design and economics as functions of design parameters and operating conditions for coal-fired electric-generating units. The model allows evaluation of several potential utility design and operating conditions for quick comparative costs of lime-spray drying options on a common-cost basis. Two significant limitations of the model are: the SO/sub 2/ removal is based on operating parameter ranges and results developed for low-sulfur coal applications (data on high-sulfur coal applications are lacking) and only an overall system SO/sub 2/ removal efficiency (without separate spray-dryer and baghouse components) is calculated. The model projections using medium- (2% sulfur) and high-sulfur coal may be in error, with error increasing with increasing coal sulfur content. Means of overcoming these limitations are proposed. The users manual describes the model and instructions for its use, required input data are detailed, and sample computer runs with output are provided to guide users in identifying applications.

Research Organization:
Tennessee Valley Authority, Muscle Shoals, AL (USA). Div. of Energy Demonstrations and Technology
OSTI ID:
6755078
Report Number(s):
PB-87-140968/XAB; TVA/PE/EDT-85/20
Country of Publication:
United States
Language:
English