Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Collection efficiency of field sampling cassettes

Technical Report ·
DOI:https://doi.org/10.2172/6742134· OSTI ID:6742134
Industrial hygiene particulate samples are often collected under anisokinetic sampling conditions and in crosswinds. Experiments were conducted to quantitate errors associated with sampling under these nonideal conditions. Three types of field sampling cassettes were tested to determine particle sampling efficiencies for 0, 2, and 5 m/s winds at incidence angles of 0, 90, and 180/sup 0/. Tests were conducted in a chamber in which the cassettes or filter holders were moved to generate a relative wind. Eight filter cassettes mounted symmetrically on a horizontal arm which rotated about a vertical shaft at 250 rpm were positioned so that four cassettes moved at 2 m/s and four at 5 m/s. In addition to two each of the test cassettes, two in-line filter cassettes equipped with isokinetic probes were mounted on the arm. Mass, or number of particles, collected by test cassettes and isokinetic samplers was compared to that collected by stationary filters placed near the rotating arm. Results from tests in the rotating arm chamber were checked against similar tests made in a turbulent flow wind tunnel. Sampling efficiencies were compared to theoretical values calculated from Belyaev and Levin's theory, and Davies' modification for calm air sampling. Satisfactory agreement was obtained for 5-..mu..m D/sub ae/ particles; however, considerable discrepancy was noted with larger particles. The results indicate that corrections must be made to determine concentration when particles collected under nonideal sampling conditions are larger than approx. 5-..mu..m D/sub ae/.
Research Organization:
Los Alamos Scientific Lab., NM (USA)
DOE Contract Number:
W-7405-ENG-36
OSTI ID:
6742134
Report Number(s):
LA-8640-MS
Country of Publication:
United States
Language:
English

Similar Records

Aerosol sampling efficiency of 37 mm filter cassettes
Journal Article · Sun Nov 30 23:00:00 EST 1986 · Am. Ind. Hyg. Assoc. J.; (United States) · OSTI ID:6801021

Testing of a personal-filter cassette with a circumferential orifice
Technical Report · Sun May 01 00:00:00 EDT 1983 · OSTI ID:6508109

A model for evaluating the error associated with anisokinetic sampling in the measurement of particle concentrations in dusts emitted from stacks
Journal Article · Thu Dec 31 23:00:00 EST 1992 · International Chemical Engineering (A Quarterly Journal of Translations from Russia, Eastern Europe and Asia); (United States) · OSTI ID:6529491