Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Reactivity anomalies in the Fast Flux Test Facility; An evaluation of data from cycles 1 through 8

Journal Article · · Nuclear Technology; (USA)
OSTI ID:6740977
;  [1]
  1. Westinghouse Hanford Co., Richland, WA (USA)

Experience using an automated core reactivity monitoring technique at the Fast Flux Test Facility (FFTF) through eight operating cycles is described. This technique relies on comparing predicted-to-measured rod positions to detect any anomalous (or unpredicted) core reactivity changes. Reactivity worth predictions of core state changes (temperature and irradiation changes) and compensating control rod movements are required for the rod position comparison. A substantial data base now exists to evaluate changes in temperature feedback reactivity effects operational in the FFTF, rod worth changes due to core loading, temperature and irradiation effects, and burnup effects associated with transmutation of fuel materials. This work focuses on resolving observed reactivity anomalies by evaluating the prediction models using additional zero-power rod worth measurement data along with calculations of rod worths and burnup rates for each cycle using cross-section data processed from the latest ENDF/B-V data set.

OSTI ID:
6740977
Journal Information:
Nuclear Technology; (USA), Journal Name: Nuclear Technology; (USA) Vol. 89:1; ISSN NUTYB; ISSN 0029-5450
Country of Publication:
United States
Language:
English