The ability to disassemble an irradiated Fast Flux Test Facility (FFTF) Driver Fuel Assembly (DFA) is important both to the continued operation of the FFTF and the future of the Breeder Reactor Program. At the FFTF, DFA's with up to three (3)* kilowatts of decay heat will be placed in the Interim Examination and Maintenance (IEM) Cell for disassembly and nondestructive examination. This process includes sodium removal, duct measurement, duct cutting and pulling, fuel pin removal, and component disposition to other laboratories for destructive examination.