SRC burn test in 700-hp oil-designed boiler. Annex Volume C. Boiler emission report. Final technical report
The Solvent-Refined Coal (SRC) test burn program was conducted at the Pittsburgh Energy Technology Center (PETC) located in Bruceton, Pa. One of the objectives of the study was to determine the feasibility of burning SRC fuels in boilers set up for fuel oil firing and to characterize emissions. Testing was conducted on the 700-hp oil-fired boiler used for research projects. No. 6 fuel oil was used for baseline data comparison, and the following SRC fuels were tested: SRC Fuel (pulverized SRC), SRC Residual Oil, and SRC-Water Slurry. Uncontrolled particulate emission rates averaged 0.9243 lb/10/sup 6/ Btu for SRC Fuel, 0.1970 lb/10/sup 6/ Btu for SRC Residual Oil, and 0.9085 lb/10/sup 6/ Btu for SRC-Water Slurry. On a lb/10/sup 6/ Btu basis, emissions from SRC Residual Oil averaged 79 and 78%, respectively, lower than the SRC Fuel and SRC-Water Slurry. The lower SRC Residual Oil emissions were due, in part, to the lower ash content of the oil and more efficient combustion. The SRC Fuel had the highest emission rate, but only 2% higher than the SRC-Water Slurry. Each fuel type was tested under variable boiler operating parameters to determine its effect on boiler emissions. The program successfully demonstrated that the SRC fuels could be burned in fuel oil boilers modified to handle SRC fuels. This report details the particulate emission program and results from testing conducted at the boiler outlet located before the mobile precipitator take-off duct. The sampling method was EPA Method 17, which uses an in-stack filter.
- Research Organization:
- WFI Sciences Co., Coraopolis, PA (USA)
- DOE Contract Number:
- AC05-78OR03054
- OSTI ID:
- 6727890
- Report Number(s):
- DOE/OR/03054-37-Annex-Vol.C; ON: DE84015197
- Country of Publication:
- United States
- Language:
- English
Similar Records
SRC burn test in 700-hp oil-designed boiler. Annex Volume F. Independent test evaluation. Final technical report
SRC burn test in 700-hp oil-designed boiler. Annex Volume E. Evaluation of fabric filter for particulate emission control. Final technical report
SRC burn test in 700-hp oil-designed boiler. Annex Volume B. DOE-Pittsburgh Energy Technology Center report. Final technical report
Technical Report
·
Thu Sep 01 00:00:00 EDT 1983
·
OSTI ID:6754493
SRC burn test in 700-hp oil-designed boiler. Annex Volume E. Evaluation of fabric filter for particulate emission control. Final technical report
Technical Report
·
Thu Sep 01 00:00:00 EDT 1983
·
OSTI ID:6744496
SRC burn test in 700-hp oil-designed boiler. Annex Volume B. DOE-Pittsburgh Energy Technology Center report. Final technical report
Technical Report
·
Thu Sep 01 00:00:00 EDT 1983
·
OSTI ID:7090528
Related Subjects
01 COAL, LIGNITE, AND PEAT
010405* -- Coal
Lignite
& Peat-- Hydrogenation & Liquefaction
BOILER FUELS
BOILERS
CHEMICAL REACTIONS
COAL LIQUEFACTION
COMBUSTION
DATA
ELECTROSTATIC PRECIPITATORS
EMISSION
EQUIPMENT
EXPERIMENTAL DATA
FABRIC FILTERS
FILTERS
FUELS
INFORMATION
LIQUEFACTION
NUMERICAL DATA
OXIDATION
PARTICLES
PARTICULATES
PERFORMANCE TESTING
POLLUTION CONTROL EQUIPMENT
SAMPLING
SOLVENT-REFINED COAL
SRC PROCESS
TEST FACILITIES
TESTING
THERMOCHEMICAL PROCESSES
010405* -- Coal
Lignite
& Peat-- Hydrogenation & Liquefaction
BOILER FUELS
BOILERS
CHEMICAL REACTIONS
COAL LIQUEFACTION
COMBUSTION
DATA
ELECTROSTATIC PRECIPITATORS
EMISSION
EQUIPMENT
EXPERIMENTAL DATA
FABRIC FILTERS
FILTERS
FUELS
INFORMATION
LIQUEFACTION
NUMERICAL DATA
OXIDATION
PARTICLES
PARTICULATES
PERFORMANCE TESTING
POLLUTION CONTROL EQUIPMENT
SAMPLING
SOLVENT-REFINED COAL
SRC PROCESS
TEST FACILITIES
TESTING
THERMOCHEMICAL PROCESSES