Fuel-cladding chemical interaction in mixed-oxide fuel at high burnup

Conference ·
DOI:https://doi.org/10.13182/NT84-A33337· OSTI ID:6724337
The HEDL FCCI correlation has been expanded to peak burnups up to 14.5 at. %. Increases in depth of interaction were found to be linear with burnup to approximately twice the FFTF goal burnup. Examinations of the peak burnup pin P-23A-18 indicates that it was very close to a true end-of-life breach, demonstrating a substantial burnup capability for FFTF reference design mixed-oxide fuel operating at high cladding temperatures.
Research Organization:
Hanford Engineering Development Lab., Richland, WA (USA)
DOE Contract Number:
AC14-76FF02170
OSTI ID:
6724337
Report Number(s):
HEDL-SA-2206-FP; CONF-801107-49
Country of Publication:
United States
Language:
English