Technical notes for the conceptual design for an atmospheric fluidized-bed direct combustion power generating plant. [570 MWe plant]

Technical Report ·
DOI:https://doi.org/10.2172/6722028· OSTI ID:6722028
The design, arrangement, thermodynamics, and economics of a 592 MW(e) (nominal gross) electric power generating plant equipped with a Babcock and Wilcox Company (B and W) atmospheric fluidized bed (AFB) boiler are described. Information is included on capital and operating costs, process systems, electrical systems, control and instrumentation, and environmental systems. This document represents a portion of an overall report describing the conceptual designs of two atmospheric fluidized bed boilers and balance of plants for the generation of electric power and the analysis and comparison of these conceptual designs to a conventional pulverized coal-fired electric power generation plant equipped with a wet limestone flue gas desulfurization system.
Research Organization:
Stone and Webster Engineering Corp., New York (USA)
Sponsoring Organization:
USDOE
OSTI ID:
6722028
Report Number(s):
HCP/T2583-01/2
Country of Publication:
United States
Language:
English