Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Regulatory and backfit analysis: Unresolved safety issue A-45, shutdown decay heat removal requirements

Technical Report ·
OSTI ID:6720072
All light water reactors require decay heat to be removed subsequent to reactor shutdown. Interruption of the decay heat removal function could lead to severe consequences. Concerns about the reliability of the systems and components that assist in the decay heat removal process and the potentially severe consequences of a complete loss of decay heat removal resulted in establishing the requirements for decay heat removal as an unresolved safety issue (USI) designated USI A-45, ''Shutdown Decay Heat Removal Requirements.'' This report presents the regulatory analysis for USI A-45. It includes (1) a summary of the issue, (2) the proposed technical resolution, (3) alternative resolutions considered by the Nuclear Regulatory Commission, (4) an assessment of the benefits and costs of all alternatives considered, and (5) the decision rationale. 23 refs., 9 figs., 39 tabs.
Research Organization:
Nuclear Regulatory Commission, Washington, DC (USA). Div. of Safety Issue Resolution
OSTI ID:
6720072
Report Number(s):
NUREG-1289; ON: TI89003025
Country of Publication:
United States
Language:
English