Radiation dose in defecography
- Univ. Hospital Maastricht (Netherlands)
The effective dose equivalent, as an expression of total patient risk for exposure to limited areas of the body, and gonadal doses associated with hereditary effects were estimated in 67 consecutive subjects (43 women and 24 men) who underwent defecography. With use of measured entrance exposure values and data from Monte Carlo simulations, the mean effective dose equivalent was estimated at 4.9 mSv +/- 1.6 (490 mrem +/- 160) for women and 0.6 mSv +/- 0.2 (60 mrem +/- 20) for men. The ovarian dose was 15 mSv +/- 5 (1.5 rem +/- 0.5). The testes are not within the primary beam and therefore are exposed to scattered radiation only, hence the low received dose of 0.14 mSv or less (14 mrem or less). These data indicate that defecography is among the radiologic procedures associated with a considerable, but not extreme, radiation dose.
- OSTI ID:
- 6715012
- Journal Information:
- Radiology; (USA), Vol. 176:1; ISSN 0033-8419
- Country of Publication:
- United States
- Language:
- English
Similar Records
Radiation dose to patient and personnel during extracorporeal shock wave lithotripsy
RADIATION EXPOSURE OF THE WHOLE POPULATION
Related Subjects
GONADS
RADIATION DOSES
INTESTINES
DIGESTIVE SYSTEM DISEASES
DOSE EQUIVALENTS
MONTE CARLO METHOD
PATIENTS
RISK ASSESSMENT
SCATTERING
BODY
DIGESTIVE SYSTEM
DISEASES
DOSES
GASTROINTESTINAL TRACT
ORGANS
560151* - Radiation Effects on Animals- Man