Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Magnetic field effects on endcap EM calorimetry in SDC

Technical Report ·
DOI:https://doi.org/10.2172/6712502· OSTI ID:6712502
The SDC calorimeter will be immersed in a strong magnetic field in the endcap region because of the solenoid which supplies the SDC tracking field. This flux must be returned through the endcap region of the electromagnetic (EM) and hadronic (HAD) calorimeters. Since magnetic fields are known to induce changes in the light output of plastic scintillator, the endcap will need to be recalibrated once the solenoid is energized. In addition, gradients in the field will create nonuniformities in the calorimetric response. The induced constant term'' in the EM and HAD calorimeters due to the inhomogeneities induced by the magnetic field are here evaluated in order to see that SDC performance specifications are not compromised.
Research Organization:
Fermi National Accelerator Lab., Batavia, IL (United States)
Sponsoring Organization:
DOE; USDOE, Washington, DC (United States)
DOE Contract Number:
AC02-76CH03000
OSTI ID:
6712502
Report Number(s):
FNAL-TM-1826; ON: DE93008371
Country of Publication:
United States
Language:
English