Phase contrast imaging system for TEXT-U

Journal Article · · Review of Scientific Instruments; (United States)
DOI:https://doi.org/10.1063/1.1146380· OSTI ID:6711998
; ;  [1]
  1. The University of Texas at Austin, Austin, Texas 78712 (United States)
A diagnostic to study plasma density fluctuations, phase contrast imaging has been developed for the Texas Experimental Tokamak-Upgrade. The diagnostic has a sensitivity of about 10[sup [minus]4] [ital n][sub [ital e]0] and is capable of detecting a wide range of wave numbers (0.5--12 cm[sup [minus]1]) with a bandwidth of 500 kHz. The design of the diagnostic, some results of acoustic calibration tests, and preliminary results of simulation of expected spectra are presented.
DOE Contract Number:
FG05-88ER53267
OSTI ID:
6711998
Journal Information:
Review of Scientific Instruments; (United States), Journal Name: Review of Scientific Instruments; (United States) Vol. 66:1; ISSN 0034-6748; ISSN RSINAK
Country of Publication:
United States
Language:
English