MLM polychromator monitoring soft-x-ray spectral line emissions of C, O, and Fe used in transport studies of the Phaedrus-T tokamak plasma during ohmic, rf-heated, and H-mode discharges
Journal Article
·
· Review of Scientific Instruments; (United States)
- The Johns Hopkins University, Baltimore, Maryland 21218 (United States)
The MLM (multilayer mirror) polychromator has two modes of operation. In the first mode, it simultaneously monitors the Ly [alpha] and [beta] emissions of H-like O at 19.0 and 16.0 A, respectively, the Ly [alpha] emission of C at 33.7 A, and the singlet and triplet transitions of He-like C at 40.5 A. In the second mode, it simultaneously monitors the Ly [alpha] and [beta] emissions of H-like C at 33.7 and 28.5 A, respectively, as well as the 15.6 and 93.9 A emissions of F-like Fe. The MLM polychromator has a wavelength resolution that varies from 0.3 A at 16.0 A to 2 A at 40.5 A and 7 A at 93.9 A. It was mounted on the midplane of the Phaedrus-T tokamak with its line of sight along the major radius. On a shot by shot basis, the MLM polychromator, with a temporal resolution of 1 ms and a spatial resolution of 1 cm, scanned the plasma in the [ital z] direction [plus minus]15 cm from the toroidal magnetic axis. Vertical asymmetries in the soft x-ray spectral line brightness profiles were measured and found to depend on the direction of [ital B][sub [ital T]]. The brightness profiles were inverted and modeled with a poloidally asymmetric Gaussian emissivity profile. The measured results were compared with the predicted emissivity profiles to determine the transport of carbon.
- DOE Contract Number:
- FG02-86ER53214
- OSTI ID:
- 6710985
- Journal Information:
- Review of Scientific Instruments; (United States), Journal Name: Review of Scientific Instruments; (United States) Vol. 66:1; ISSN 0034-6748; ISSN RSINAK
- Country of Publication:
- United States
- Language:
- English
Similar Records
MLM-based monochromator for molybdenum impurity monitoring on the Alcator C-MOD tokamak in the 30--130 A range
How to beat the low resolution of multilayer mirror spectra (invited)
Measurements of molybdenum radiation in the Alcator C-Mod tokamak using a multilayer mirror soft x-ray polychromator
Journal Article
·
Thu Oct 01 00:00:00 EDT 1992
· Review of Scientific Instruments; (United States)
·
OSTI ID:7009204
How to beat the low resolution of multilayer mirror spectra (invited)
Journal Article
·
Tue Dec 31 23:00:00 EST 1996
· Review of Scientific Instruments
·
OSTI ID:451938
Measurements of molybdenum radiation in the Alcator C-Mod tokamak using a multilayer mirror soft x-ray polychromator
Journal Article
·
Sat Dec 31 23:00:00 EST 1994
· Review of Scientific Instruments; (United States)
·
OSTI ID:7060130
Related Subjects
70 PLASMA PHYSICS AND FUSION TECHNOLOGY
700320* -- Plasma Diagnostic Techniques & Instrumentation-- (1992-)
CARBON
ELECTROMAGNETIC RADIATION
ELECTRON DENSITY
ELECTRON TEMPERATURE
ELEMENTS
EMISSION SPECTRA
IONIZING RADIATIONS
IRON
MAGNETIC MIRRORS
METALS
NONMETALS
OPEN PLASMA DEVICES
OXYGEN
PHAEDRUS MIRROR DEVICES
PLASMA DIAGNOSTICS
RADIATIONS
SOFT X RADIATION
SPECTRA
TANDEM MIRRORS
THERMONUCLEAR DEVICES
TRANSITION ELEMENTS
X RADIATION
X-RAY SPECTRA
700320* -- Plasma Diagnostic Techniques & Instrumentation-- (1992-)
CARBON
ELECTROMAGNETIC RADIATION
ELECTRON DENSITY
ELECTRON TEMPERATURE
ELEMENTS
EMISSION SPECTRA
IONIZING RADIATIONS
IRON
MAGNETIC MIRRORS
METALS
NONMETALS
OPEN PLASMA DEVICES
OXYGEN
PHAEDRUS MIRROR DEVICES
PLASMA DIAGNOSTICS
RADIATIONS
SOFT X RADIATION
SPECTRA
TANDEM MIRRORS
THERMONUCLEAR DEVICES
TRANSITION ELEMENTS
X RADIATION
X-RAY SPECTRA