Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Some target assay uncertainties for passive neutron coincidence counting

Conference ·
OSTI ID:6709462
This paper provides some target assay uncertainties for passive neutron coincidence counting of plutonium metal, oxide, mixed oxide, and scrap and waste. The target values are based in part on past user experience and in part on the estimated results from new coincidence counting techniques that are under development. The paper summarizes assay error sources and the new coincidence techniques, and recommends the technique that is likely to yield the lowest assay uncertainty for a given material type. These target assay uncertainties are intended to be useful for NDA instrument selection and assay variance propagation studies for both new and existing facilities. 14 refs., 3 tabs.
Research Organization:
Los Alamos National Lab., NM (USA)
Sponsoring Organization:
DOE/DP
DOE Contract Number:
W-7405-ENG-36
OSTI ID:
6709462
Report Number(s):
LA-UR-90-2355; CONF-9007106--44; ON: DE90014928
Country of Publication:
United States
Language:
English