Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Fabricate, calibrate, and test a dosimeter for integration into the CRRES (Combined Release and Radiation Effects Satellite) satellite. Technical report

Technical Report ·
OSTI ID:6707305
A Space Radiation Dosimeter was fabricated, calibrated, tested, and has undergone successful integration testing in the CRRES spacecraft. This Dosimeter is essentially identical to that previously designed, fabricated, calibrated, tested, and integrated into the DMSP F7 satellite. These dosimeters are primarily designed to measure the dose from electrons of greater than 1 MeV to greater than 10 MeV in four channels. Each channel has a different thickness aluminum dome.
Research Organization:
Panametrics, Inc., Waltham, MA (USA)
OSTI ID:
6707305
Report Number(s):
AD-A-196496/4/XAB; SCIENTIFIC-5
Country of Publication:
United States
Language:
English