Validation data for photochemical mechanisms. Final report, May 1984-April 1986

Technical Report ·
OSTI ID:6707026
The report describes the quality-assurance and data-processing procedures and systems used at the UNC outdoor smog chamber facility. The facility is used to measure the reactants and products that participate in the photochemical smog formation process. The intent of the quality-assurance effort is to insure the collection, transfer, processing and reporting of accurate, high-resolution data without loss or distortion. The document describes the calibration techniques and data-processing procedures and the processing of the experimental data. A description and examples of the format of the final documentation and data file are given. Also included are the quality-assurance steps and accuracy and precision aspects of the data.
Research Organization:
North Carolina Univ., Chapel Hill (USA). Dept. of Environmental Sciences and Engineering