Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Measured absorbed dose rates from semi-infinite hemispherical volumes of /sup 133/Xe

Journal Article · · Health Phys.; (United States)
Surface absorbed dose rates from different hemispheric volumes of /sup 133/Xe have been measured directly with an extrapolation chamber. The results indicate that a linear relationship exists between the radius of the cloud volume and the surface absorbed dose rate for radii between 0 and 23 cm. If cloud volumes with radii larger than 23 cm are taken to be infinite with respect to the range of the charged particles emitted, the absorbed dose rate calculated based on that assumption will be within the uncertainty of any measurement of absorbed dose rate that might be made. For hemispheric volumes having radii less than or equal to 23 cm, the surface absorbed dose rate in tissue-equivalent material, in mGy h-1, is approximated (+/- 20%) by the product of (1.30 mGy h-1 cm-1 kBq-1 cm3) X (cloud radius, cm) X (cloud activity concentration, kBq cm-3).
Research Organization:
Univ. of Minnesota, Minneapolis (USA)
OSTI ID:
6689182
Journal Information:
Health Phys.; (United States), Journal Name: Health Phys.; (United States) Vol. 51:1; ISSN HLTPA
Country of Publication:
United States
Language:
English