SBLOCA outside containment at Browns Ferry Unit One: accident sequence analysis. [Small break]
This study describes the predicted response of Unit 1 at the Browns Ferry Nuclear Plant to a postulated small-break loss-of-coolant accident outside of the primary containment. The break has been assumed to occur in the scram discharge volume piping immediately following a reactor scram that cannot be reset. The events before core uncovering are discussed for both the worst-case accident sequence without operator action and for the more likely sequences with operator action. Without operator action, the events after core uncovering would include core meltdown and subsequent containment failure, and this event sequence has been determined through use of the MARCH code. An estimate of the magnitude and timing of the concomitant release of the noble gas, cesium, and iodine-based fission products to the environment is provided in Volume 2 of this report.
- Research Organization:
- Oak Ridge National Lab., TN (USA)
- DOE Contract Number:
- W-7405-ENG-26
- OSTI ID:
- 6669291
- Report Number(s):
- NUREG/CR-2672-Vol.1; ORNL/TM-8119/Vol.1; ON: DE83003191
- Resource Relation:
- Other Information: Portions of document are illegible
- Country of Publication:
- United States
- Language:
- English
Similar Records
Noble gas, iodine, and cesium transport in a postulated loss of decay heat removal accident at Browns Ferry
Loss of DHR sequences at Browns Ferry Unit One - accident-sequence analysis
Related Subjects
21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS
BROWNS FERRY-1 REACTOR
LOSS OF COOLANT
COMPUTER CODES
CONTAINMENT BUILDINGS
HEAT TRANSFER
HYDRAULICS
HYDROGEN
M CODES
PRESSURE GRADIENTS
REACTOR OPERATORS
REACTOR SAFETY
TEMPERATURE GRADIENTS
ACCIDENTS
BWR TYPE REACTORS
CONTAINMENT
ELEMENTS
ENERGY TRANSFER
ENRICHED URANIUM REACTORS
FLUID MECHANICS
MECHANICS
MIXED SPECTRUM REACTORS
NONMETALS
PERSONNEL
POWER REACTORS
REACTOR ACCIDENTS
REACTORS
SAFETY
WATER COOLED REACTORS
WATER MODERATED REACTORS
220900* - Nuclear Reactor Technology- Reactor Safety
210100 - Power Reactors
Nonbreeding
Light-Water Moderated
Boiling Water Cooled