skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Effect of secondary flow caused by Hall currents in compressible boundary layers near the insulating wall of an MHD generator

Journal Article · · High Temp. (Engl. Transl.); (United States)
OSTI ID:6665642

The transverse flow near the insulating wall for a compressible turbulent flow of seeded combustion products is analyzed with the help of the Patankar--Spalding numerical method. The results show that for the U-25 generator of the bypass type, the transverse component of the flow velocity equals roughly-equal5% of the axial velocity and its maximum is situated near the walls.

Research Organization:
Baba Atomic Research Center, Bombay
OSTI ID:
6665642
Journal Information:
High Temp. (Engl. Transl.); (United States), Vol. 19:5
Country of Publication:
United States
Language:
English