skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Examination results on TMI-2 LPM charge converters YM-AMP-7023 and YM-AMP-7025

Technical Report ·
DOI:https://doi.org/10.2172/6663935· OSTI ID:6663935

During, and for several months after the Three Mile Island Unit 2 accident, the reactor vessel and two steam generators were closely monitored for the existence of coolant system loose parts. We have examined two Endevco charge converters removed from the loose parts monitoring system inside containment and found the devices to be severely degraded by gamma radiation. Because of this, it is likely that the loose parts readings made during the accident were lower than actual levels. This report discusses the cause of failure, our estimates of the total gamma radiation doses received by the charge converters, and our recommendations for changes in U.S. Nuclear Regulatory Guide 1.133.

Research Organization:
Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)
DOE Contract Number:
AC07-76ID01570
OSTI ID:
6663935
Report Number(s):
GEND-020; ON: DE83002893
Resource Relation:
Other Information: Portions of document are illegible. Printed copy available until stock is exhausted
Country of Publication:
United States
Language:
English