Measurement of neutron dose and spectra at light-water reactors
Conference
·
OSTI ID:6663516
In choosing one dosimeter over another, both sensitivity and precision must be addressed. It has been determined that dosimeters employing NTA film lack adequate sensitivity for use inside containment of nuclear plants. From this study, it is apparent that CR-39 and polycarbonate track etch films used without radiators are also inadequate. The rest of the dosimeters tested displayed adequate sensitivity. The two general types of dosimeters which comprise that group are: (1) TLDs and (2) the polycarbonate track etch which was used in conjunction with (n, ..cap alpha..) radiators. The precision of the TLD dosimeter depends on the calibration technique and response correction technique. TLD dosimeters calibrated to D/sub 2/O-moderated californium-252 or corrected based on 9- to 3-in. sphere response rates seemed to function best inside reactor containment. Polycarbonate track etch film with (n, ..cap alpha..) radiators was found to be sensitive enough for use inside reactor containment; however, the standard deviation for the results was roughly twice the value of the most precise TLD albedo dosimeters. Also, several of the polycarbonate dosimeters saturated, rendering any evaluation impossible.
- Research Organization:
- Pacific Northwest Lab., Richland, WA (USA)
- DOE Contract Number:
- AC06-76RL01830
- OSTI ID:
- 6663516
- Report Number(s):
- PNL-SA-10728; CONF-821037-40; ON: DE83002691
- Country of Publication:
- United States
- Language:
- English
Similar Records
Neutron Spectra and Dose Equivalent Inside Nuclear Power Reactor Containment
Neutron-dosimeter performance and associated calibrations at nuclear power plants
Nevada Test Site Neutron Dosimetry-Problems/Solutions
Technical Report
·
Sat Aug 01 00:00:00 EDT 1981
·
OSTI ID:1079972
Neutron-dosimeter performance and associated calibrations at nuclear power plants
Technical Report
·
Thu Jul 01 00:00:00 EDT 1982
·
OSTI ID:5276021
Nevada Test Site Neutron Dosimetry-Problems/Solutions
Conference
·
Tue Jun 04 00:00:00 EDT 1991
·
OSTI ID:5271630
Related Subjects
22 GENERAL STUDIES OF NUCLEAR REACTORS
220200* -- Nuclear Reactor Technology-- Components & Accessories
440102 -- Radiation Instrumentation-- Radiation Dosemeters
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY
CARBON COMPOUNDS
CARBONATES
COMPARATIVE EVALUATIONS
DIELECTRIC TRACK DETECTORS
DOSEMETERS
DOSES
DOSIMETRY
LUMINESCENT DOSEMETERS
MEASURING INSTRUMENTS
NEUTRON DOSIMETRY
NUCLEAR FACILITIES
NUCLEAR POWER PLANTS
OXYGEN COMPOUNDS
POLYCARBONATES
POWER PLANTS
RADIATION DETECTORS
RADIATION DOSES
REACTORS
THERMAL POWER PLANTS
THERMOLUMINESCENT DOSEMETERS
WATER COOLED REACTORS
220200* -- Nuclear Reactor Technology-- Components & Accessories
440102 -- Radiation Instrumentation-- Radiation Dosemeters
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY
CARBON COMPOUNDS
CARBONATES
COMPARATIVE EVALUATIONS
DIELECTRIC TRACK DETECTORS
DOSEMETERS
DOSES
DOSIMETRY
LUMINESCENT DOSEMETERS
MEASURING INSTRUMENTS
NEUTRON DOSIMETRY
NUCLEAR FACILITIES
NUCLEAR POWER PLANTS
OXYGEN COMPOUNDS
POLYCARBONATES
POWER PLANTS
RADIATION DETECTORS
RADIATION DOSES
REACTORS
THERMAL POWER PLANTS
THERMOLUMINESCENT DOSEMETERS
WATER COOLED REACTORS