skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Congeneration feasibility: Otis Elevator Company and Polychrome Corporation. Final report

Technical Report ·
OSTI ID:6663454

This report summarizes an investigation of the technical and economic feasibility of cogenerating electric and thermal power at two manufacturing plants (Otis Elevator Company and Polychrome Corporation) located on neighboring properties in Yonkers, NY. Existing electrical- and steam-producing equipment and energy consumption date are summarized. Alternative cases examined include electrical energy generation, electrical energy generation with waste heat recovery and a combined cycle case. Also reported are life cycle cost economic evaluations including simple payback period and return-on-investment indices. While it was concluded that cogeneration of heat and electricity at these industrial plant sites would not be economically viable, this detailed study provides valuable insight into the types of problems encountered when considering cogeneration feasibility.

Research Organization:
Pope, Evans and Robbins, Inc., New York (USA)
OSTI ID:
6663454
Report Number(s):
PB-82-263526
Country of Publication:
United States
Language:
English